China
Email
 
 
Home   |   About us   |   Products   |   Certificate   |   HD Video   |   PDF Catalog Library   |   Contact us
 
 
Electro-Mechanical Meters
Electronic Meters
DIN rail Meters
Analog Panel Meter
Digit Panel Meter
Multi-function power meter
Digital Meter
Temperature Controller
Products >> Multi-function power meter > 2S series HD194Z(E)
2S series HD194Z(E) Network (multi-function) Power Meter

1. Summarize:

HD194Z£¨E£©series of network (multi-function) power meter set of programmable power measurement¡¢digital display¡¢digital communication and a variety of input¡¢output function with smart power meter.
HD194Z (E) series of power meters can measure a variety of commonly used parameters and the active/ reactive power, the greatest amount of need and have a wide range of expansion of function modules: digital communication modules, digital switching modules, electric power pulse modules, and analog pulse output module to send the quantitative, can be selected flexibly. All data are available through RS-485 communication using MODBUS protocol I read, the volume of input switches can be used to monitor the status of switches; the output switch can be remote control, the more alarm; analog variables can be output to replace the traditional transmission browser. HD194Z (E) family of network (multi-) power meter can adapt to all voltage levels and the connection mode, to meet a variety of specifications of the distribution of high and low pressure switch cabinet, focus on installation.

2. Type and meaning:

3. Performance index:

Technical parameters

Index

Referenced standards

Basic power

GB/T13978-1992

Active electric power

GB/T13850-1998£¨IEC688-1992£©

Reactive electric power

Reactive 1.0, other 0.5

Accuracy class

Input

applicable network

Single phase, three phase 3 wire, three phase 4 wire

Voltage

Rated value

AC 100V¡¢220V¡¢380V

Overload

1.2 times Successively£¬2 times/10s

Power loss

< 0.4VA/phase

impedance

¡Ý200k¦¸

Current

Rated value

AC 1A¡¢5A

Overload

1.2 times Successively£¬10 times/10s

Power loss

< 0.2VA/phase

impedance

¡Ü0.1¦¸

Frequency

50¡À5Hz, 60¡À5Hz

Output

electric power pulse

2-way electric power pulse, 4-quadrant electric power measurement

digital communication interface

RS485/Modbus-RTU baud rate 1200/2400/4800/9600

switching input

3 to 8 pole switching input, dry contact or wet contact input

Switching output

2 to 4 pole relay output

Analog output

2 to 4 pole analog transmission output, 4~20mA/0-20mA/0-5V

Power supply

Voltage range

AC, DC: 80V ~ 290V, DC 20 ~ 60V(optional)

Power loss

< 5VA

Insulation resistance

¡Ý100M¦¸

Power frequency withstand voltage

2Kv/1min(AC effective value for test voltage £¬input/enclosure/power supply belong)

Protection level of cover

IP52

Mean time between failures MTBF

¡Ý50000h

EMC

Electrostatic discharge test

GB/T17626.2-1998£¨IEC61000-4-2£©class 4

Electrical fast transplant/burst immunity test

GB/T17626.4-1998£¨IEC61000-4-4£©class 3 test voltage: voltage current 1kV; power: 2 kV

Surge immunity test

GB/T17626.5-1998£¨IEC61000-4-5£©class 4

Ambient condition

Temperature

Working: -10¡æ~+55¡æ, store: -25¡æ~+70¡æ

Relative humidity

¡Ü90%RH, non-condensing, non-corrosive gas site

Altitude

¡Ü2500m

4. Products:

2S series

1. Installation method: screen installation (hold size: 111¡Á111 mm)

2. Display


2SY: measure three phase voltage, three phase current, active power, reactive power, frequency, power factor, active energy (absorb) and reactive energy (inductive), By switching means and LCD display the above power parameters, and to perserve and display the last month, 2 month ago electric power and peak balka time-sharing power.

 

 


2S4: measure three phase voltage, three phase current, active power, reactive power, frequency, power factor, active energy (absorb) and reactive energy (inductive), By switching means and 3 row 5 digits LED, and indicator light above parameters.

 

 

 

2S7: measure 4-quadrant electric power: active energy (Absorption and release), reactive energy (Inductive and capacitive), adopt 2 row 6 digits LED display type, display active energy (absorb) and reactive energy (inductive), when press the switch button, the meter will display active energy (absorb) and reactive energy (inductive), and continue for some time after the return to display active power (absorb) and reactive energy (inductive).

 

 

2S9: measure 3 current and one active energy, adopt 3 row 4 digits, LED display current, 1 row 6 digits LED display energy.

 

 

 

3. Outline dimension:

 

 

 

 

 

 